CVE-2024-44102
Essential information
- Published
- 12/11/2024 13:15
- Modified
- 13/11/2024 23:05
- Author
- —
- Creator
- —
- CVSS
- 10.0 CRITICAL (v3.1)
- CISA KEV
- No
- CWE
- —
- CVSS vector
-
—
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H—
CVSS metrics
- Access vector
- —
- Access complexity
- —
- Authentication
- —
- Confidentiality impact
- —
- Integrity impact
- —
- Availability impact
- —
- Exploitability
- —
- Remediation level
- —
- Report confidence
- —
- Temporal score
- —
- Attack vector
- NETWORK
- Attack complexity
- LOW
- Privileges required
- NONE
- User interaction
- NONE
- Scope
- CHANGED
- Confidentiality impact
- HIGH
- Integrity impact
- HIGH
- Availability impact
- HIGH
- Exploit code maturity
- —
- Remediation level
- —
- Report confidence
- —
- Temporal score
- —
- Attack vector
- —
- Attack complexity
- —
- Attack requirements
- —
- Privileges required
- —
- User interaction
- —
- Confidentiality (V)
- —
- Confidentiality (S)
- —
- Integrity (V)
- —
- Integrity (S)
- —
- Availability (V)
- —
- Availability (S)
- —
- Exploit maturity
- —
Description
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
NVD status
- Status
- Analyzed — CVE has been marked for Analysis. Normally once in this state the CVE will be analyzed by NVD staff within 24 hours.
- Source
- [email protected]
- NVD
- View on NVD
Affected products (CPE)
| Product | CPE |
|---|---|
| siemens / telecontrol server basic | cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:* |