216.73.217.22

CVE-2026-25599

· Published 01/06/2026 11:16 · Modified 01/06/2026 18:02

Labels: CVE-2026-25599 2026-06-01CVE-2026-25599CWE-79a6d3dc9e-0591-4a13-bce7-0f5b31ff6158

Essential information

Published
01/06/2026 11:16
Modified
01/06/2026 18:02
Author
Creator
CVSS
6.3 MEDIUM (v3.1)
CISA KEV
No
CWE
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L

CVSS metrics

Description

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

NVD status

Status
Awaiting Analysis — CVE has been recently published to the CVE List and has been received by the NVD.
Source
a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
NVD
View on NVD

Affected products (CPE)

ProductCPE
orca / heat pump cpe:2.3:a:orca:heat_pump:*:*:*:*:*:*:*:*
orca / control server cpe:2.3:a:orca:control_server:*:*:*:*:*:*:*:*

References