216.73.217.22

CVE-2026-30956

· Published 10/03/2026 18:18 · Modified 11/03/2026 13:53

Labels: CVE-2026-30956 2026-03-10CVE-2026-30956CWE-285[email protected]

Essential information

Published
10/03/2026 18:18
Modified
11/03/2026 13:53
Author
Creator
CVSS
9.9 CRITICAL (v3.1)
CISA KEV
No
CWE
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

CVSS metrics

Description

OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. Because the server trusts this client-supplied header, internal permission checks in BasePermission are skipped and tenant scoping is disabled. This allows attackers to access project data belonging to other tenants, read sensitive User fields via nested relations, leak plaintext resetPasswordToken, and reset the victim’s password and fully take over the account. This results in cross‑tenant data exposure and full account takeover. This vulnerability is fixed in 10.0.21.

NVD status

Status
Undergoing Analysis — CVE has been recently published to the CVE List and has been received by the NVD.
Source
[email protected]
NVD
View on NVD

Affected products (CPE)

ProductCPE
oneuptime / oneuptime cpe:2.3:a:oneuptime:oneuptime:<10.0.21:*:*:*:*:*:*:*

References